Local Design Criteria

Building and Environmental Design Criteria

  • Ground snow load: 35 psf
  • Wind design:
    • Wind speed (Vult): 115 mph
    • Topographic effects: No
    • Special wind region: No
    • Windborne debris zone: No
  • Seismic Design Category: B
  • Subject to damage from:
    • Weathering: Severe
    • Frost line depth: 36 inches
    • Termite risk: Slight to moderate
  • Ice barrier underlayment required: Yes
  • Flood hazards:
    • Date of entry in NFIP: 1978
    • Current FIRM map revision dates: 2007 / 2017
  • Air freezing index: ≤1,500º F
  • Mean annual temperature: 50º F

Manual J Design Criteria

  • Elevation: 5,160 feet
  • Latitude: 40
  • Altitude correction factor: 0.84
  • Coincident wet bulb: 60º F
  • Indoor winter design relative humidity: 30 percent
  • Indoor winter design dry-bulb temperature: 70º F
  • Outdoor winter design dry-bulb temperature: 7º F
  • Heating temperature difference: 63º F
  • Daily range: High
  • Indoor summer design relative humidity: 50 percent
  • Summer design grains: -35
  • Indoor summer design dry-bulb temperature: 75º F
  • Outdoor summer design dry-bulb temperature: 92º F
  • Cooling temperature difference: 17º F